21-71

Temporary Condominium Project Review Policy: Simple Access, Jumbo/Jumbo AUS, and Jumbo Elite

Fannie Mae Lender Letter 2021-14, dated October 13, 2021, announced updated eligibility guidance on condominium projects.

This updated guidance was issued by Fannie Mae to address condo projects with aging infrastructure and signs of significant deferred maintenance in the aftermath of the collapse of the Champlain South Tower in Florida earlier this year.

Simple Access, Jumbo/Jumbo AUS and Jumbo Elite guidelines defer to Fannie Mae for general policies therefore Homebridge is updating these programs to align with Fannie Mae’s recent updated policy for condominium projects.

Significant Deferred Maintenance/Unsafe Conditions: Projects with 5 or more Attached Units

  • Loans secured by a condo in a project with five (5) or more attached units, regardless of the type of project review or review waiver are ineligible if the following applies:
    • Significant deferred maintenance, or
    • A directive from a regulatory authority or inspection agency for the project to make repairs due to unsafe conditions, or
    • A project that has failed to obtain an acceptable certificate of occupancy or pass local regulatory inspections or recertifications
  • Significant deferred maintenance includes deficiencies that meet one or more of the following criteria:
    • Full or partial evacuation of the building to complete repairs is required for more than 7 days or for an unknown timeframe, or
    • The project has deficiencies, defects, substantial damage, or deferred maintenance that:
      • Is severe enough to affect the safety, soundness, structural integrity, or habitability of the project, and/or
      • The project needs substantial repairs and rehabilitation, including many major components, and/or
      • Impedes the safe and sound functioning of one or more of the building’s major structural or mechanical elements (e.g. foundation, roof, load bearing structures, electrical system, HVAC, or plumbing
    • Projects will remain ineligible until the required repairs have been made and the repairs documented.  Acceptable documentation, showing repairs have been completed in a manner that resolves the building’s safety, soundness, structural integrity, or habitability concerns, includes:
    • An engineering or inspection report, or
    • Certificate of occupancy (must be a current CO; not the original CO), or
    • Other substantially similar documentation

Special Assessments:  Projects with 5 or more Attached Units

  • If the project has any current or planned special assessment, even if paid in full for the subject unit, Homebridge must review the assessment for acceptability.  The following documentation is required and must be retained in the loan file:
    • The reason for the special assessment, and
    • The total amount assessed and the repayment terms, and
    • Documentation to support no negative impact to the financial stability, viability, condition, and marketability of the project, and
    • Documentation the borrower was qualified with any outstanding special assessment payment
  • Additionally, the following applies:
    • The financial documents, confirming the association has the ability to fund any repairs, must be obtained
    • If the special assessment is related to safety, soundness, structural integrity, or habitability, all related repairs must be fully completed, or the project is ineligible
    • If the appraiser is unable to determine that there is no adverse impact, the project is ineligible

Reserve Requirements: Full Reviews Only

A reserve study in lieu of the condo project meeting the 10% budget reserve requirement is no longer eligible.

The Fannie Mae Full Review Questionnaire has been updated and posted on the Forms page under the Condo Specific section.  Brokers should begin using the new version, dated November 16, 2021, effective immediately.  Homebridge will accept the prior version of the Full Review Questionnaire, dated November 23, 2020 through Friday, December 10, 2021.

The updated version of the Full Review questionnaire will be required effective Monday, December 13. 2021

The Simple Access, Jumbo/Jumbo AUS and Jumbo Elite guidelines have been updated with this information and posted on the Homebridge website at www.HomebridgeWholesale.com

If you have any questions, please contact your Account Executive